摩熵化学
数据库官网
小程序
打开微信扫一扫
首页 分子通 化学资讯 化学百科 反应查询 关于我们
请输入关键词

[(8R,9S,13S,14S,17S)-3-hydroxy-13-methyl-6,7,8,9,11,12,14,15,16,17-decahydrocyclopenta[a]phenanthren-17-yl] 1-methyl-2H-pyridine-3-carboxylate | 154274-19-8

中文名称
——
中文别名
——
英文名称
[(8R,9S,13S,14S,17S)-3-hydroxy-13-methyl-6,7,8,9,11,12,14,15,16,17-decahydrocyclopenta[a]phenanthren-17-yl] 1-methyl-2H-pyridine-3-carboxylate
英文别名
——
[(8R,9S,13S,14S,17S)-3-hydroxy-13-methyl-6,7,8,9,11,12,14,15,16,17-decahydrocyclopenta[a]phenanthren-17-yl] 1-methyl-2H-pyridine-3-carboxylate化学式
CAS
154274-19-8
化学式
C25H31NO3
mdl
——
分子量
393.526
InChiKey
BDUYPBCWACSPAE-BZDYCCQFSA-N
BEILSTEIN
——
EINECS
——
  • 物化性质
  • 计算性质
  • ADMET
  • 安全信息
  • SDS
  • 制备方法与用途
  • 上下游信息
  • 反应信息
  • 文献信息
  • 表征谱图
  • 同类化合物
  • 相关功能分类
  • 相关结构分类

计算性质

  • 辛醇/水分配系数(LogP):
    5.3
  • 重原子数:
    29
  • 可旋转键数:
    3
  • 环数:
    5.0
  • sp3杂化的碳原子比例:
    0.56
  • 拓扑面积:
    49.8
  • 氢给体数:
    1
  • 氢受体数:
    4

反应信息

  • 作为产物:
    描述:
    1-methyl-3-<<<3-hydroxyestra-1,3,5(10)-trien-17β-yl>oxy>carbonyl>pyridinium iodide 在 sodium tetrahydroborate 作用下, 以 甲醇 为溶剂, 生成 [(8R,9S,13S,14S,17S)-3-hydroxy-13-methyl-6,7,8,9,11,12,14,15,16,17-decahydrocyclopenta[a]phenanthren-17-yl] 1-methyl-2H-pyridine-3-carboxylate
    参考文献:
    名称:
    Determination of estredox, a compound with sustained estradiol function, and its impurity profile by HPLC
    摘要:
    这里描述的 HPLC 方法用于 Estredox (E2CDS) 的测定和纯度测试,E2CDS 是一种具有基于氧化还原的脑靶向雌二醇化学输送系统的分子,可以对 API 和 E2CDS/ 的效力和纯度得出可靠的结论。 HPCD 复杂样品。我们进行了大量工作来分离和表征主要的潜在污染物,并确保 E2CDS(一种本质上不稳定的化合物)溶液所需的稳定性。样品溶剂和洗脱液都经过彻底测试,以避免分析过程中样品溶液发生不必要的变化。 220 或 360 nm 的 12 分钟等度测定方法简单、有依据、高度精确和准确。 E2CDS 的纯度分析在检测、稳定性和准确性方面提出了一些问题,因为紫外光谱的模式以及化合物和潜在污染物的稳定性通常差异很大。通过对 UV 光谱和影响相关化合物在溶液中行为的因素进行仔细分析,为 E2CDS 和 E2CDS/HPCD 复合样品的纯度测试开发的 20 分钟梯度方法(在 220 nm 处)已证明成为充分分离已知和未知化合物的 15-20 个峰并确定各种 E2CDS 样品纯度的可靠方法。样品杂质可以表示为 220 nm 处的面积百分比和/或近似 w/w %(如果需要),因为 6 种主要潜在污染物在 220 nm 处的相对响应因子也已确定。
    DOI:
    10.1691/ph.2008.7321
点击查看最新优质反应信息

文献信息

  • Transmucosal dosage forms for brain-targeted steroid chemical delivery systems
    申请人:Bodor S. Nicholas
    公开号:US20050059615A1
    公开(公告)日:2005-03-17
    Provided are pharmaceutical compositions of an essentially saturated complex of a steroidal chemical delivery system with cyclodextrin, formulated into a transmucosal dosage form, and methods for their use.
    本发明提供了将类固醇化学递送系统与环糊精的基本饱和复合物配制成经粘膜剂型的药物组合物及其使用方法。
  • Determination of estredox, a compound with sustained estradiol function, and its impurity profile by HPLC
    作者:Patthy、Seres、Toth-Sarudy、Hazai、Pallagi、Simay, Antal、Bodor
    DOI:10.1691/ph.2008.7321
    日期:——
    The HPLC methods described here for the assay and purity test of Estredox (E2CDS), a molecule with a redox-based, brain-targeted chemical delivery system for estradiol, allow reliable conclusions to be made on the potency and purity of API and E2CDS/HPCD complex samples. Extensive work was done to isolate and characterize the major, potential contaminants, and ensure the required stability of solutions of E2CDS, an inherently labile compound by design. Both the sample solvent and the eluent were thoroughly tested to avoid unwanted changes in sample solutions during analyses. The 12 minute isocratic assay method at 220 or 360 nm is simple, well-founded, highly precise and accurate. Purity profiling of E2CDS raised several problems in detection, stability and accuracy, owing to the fact that the pattern of the UV spectra and the stability of the compound and those of the potential contaminants often differed greatly. As a result of meticulous analysis of the UV spectra and the factors influencing the behaviour, in solution, of the compounds concerned, the 20 minute gradient method developed for the purity test, at 220 nm, of E2CDS and E2CDS/HPCD complex samples has proved to be a reliable means of adequately resolving 15–20 peaks of known and unknown compounds, and establishing the purity of various E2CDS samples. Sample impurity can be expressed as area % at 220nm, and/or as approximate w/w % (if needed), since the relative response factors, at 220 nm, of the 6 major, potential contaminants have also been determined.
    这里描述的 HPLC 方法用于 Estredox (E2CDS) 的测定和纯度测试,E2CDS 是一种具有基于氧化还原的脑靶向雌二醇化学输送系统的分子,可以对 API 和 E2CDS/ 的效力和纯度得出可靠的结论。 HPCD 复杂样品。我们进行了大量工作来分离和表征主要的潜在污染物,并确保 E2CDS(一种本质上不稳定的化合物)溶液所需的稳定性。样品溶剂和洗脱液都经过彻底测试,以避免分析过程中样品溶液发生不必要的变化。 220 或 360 nm 的 12 分钟等度测定方法简单、有依据、高度精确和准确。 E2CDS 的纯度分析在检测、稳定性和准确性方面提出了一些问题,因为紫外光谱的模式以及化合物和潜在污染物的稳定性通常差异很大。通过对 UV 光谱和影响相关化合物在溶液中行为的因素进行仔细分析,为 E2CDS 和 E2CDS/HPCD 复合样品的纯度测试开发的 20 分钟梯度方法(在 220 nm 处)已证明成为充分分离已知和未知化合物的 15-20 个峰并确定各种 E2CDS 样品纯度的可靠方法。样品杂质可以表示为 220 nm 处的面积百分比和/或近似 w/w %(如果需要),因为 6 种主要潜在污染物在 220 nm 处的相对响应因子也已确定。
查看更多